Get A Quote

Use our contact form to get a quote or call BPS at 330-220-1440

FAQ

Frequently Asked Questions

How do I adjust the vibration force?
Arrow
Simply reposition the eccentric weights on both ends of the motor shaft. The motor ships preset at 100% of its maximum force for immediate high-intensity operation.
Can this motor operate in outdoor installations?
Arrow
Yes. Its IP55 enclosure offers substantial protection against dust and low-pressure water jets. For harsh or wet environments, additional shielding may be beneficial.
What maintenance is needed for the bearings?
Arrow
Periodic greasing using Shell Alvania Grease #3 (or an approved equivalent) is required. Frequency of application depends on load, run time, and environmental conditions.
Can the KEE-84-4 be used in multiple voltage setups?
Arrow
The standard unit supports 230/460 V three-phase, but KEE vibratory motors also come in 575 V and 230/380/460 V variants. Consult the manufacturer or supplier for availability and compatibility.